Spa Quip 800 and 1200 Spa Controllers
Published 11 April 2022
Product
Spa Quip 800 and 1200 Spa Controllers Spa pool controllers used in small to medium-sized spas and swim-spas to connect and control the operation of spa components. Models: Q800-30, Q800-30LAN, Q800-30R, Q1200-35, Q1200-35R, Q1200-45, Q1200-45R and Q1200-60. Affected serial numbers include: the numbers '208' or lower (e.g. ###208######), or X05, X06, X07 and 108 (e.g. ###X05######). The serial number can be found on a white label in the outer cover of the controller housing. Only products manufactured before February 2008 are affected by this recall. How to identify the product The controller is part of the inner workings of the spa and will be found behind the spa's cabinet or under decking adjacent to the spa. The exact location of the controller will vary depending on the spa design. The simplest way to identify whether a spa is affected by this recall is to look at the spa's touchpad design. Spas with touchpads similar to those in these photographs may contain an affected controller. If unsure, consumers can email a photograph of their spa touchpad to SpaQuipRecall@davey.com.au and a team member will confirm if it is an affected spa.
Why it was recalled
The controller has a flexible socket, which means it is possible for an AMP plug to be forced into the controller upside-down. This may cause the plugged-in device or parts touching the plugged-in device to become live.
Hazard
Risk of electric shock, which can cause serious injury or death. There has been a fatality associated with this product.
Source: Product Safety Australia. RecallMatch AU provides a screening summary and is independent of the ACCC.