AUSTRALIAN PRODUCT RECALL

Astro and Canyon Guide rope access harnesses

Published 20 March 2026

Product

Astro and Canyon Guide rope access harnesses ASTRO BOD FAST harnesses, European version: C083AA00, C083AA01, C083AA02 (serial number less than 23J 9999999 999) ASTRO BOD FAST harnesses, International version: C083BA00, C083BA01, C083BA02, C083BA03, C083BA04, C083BA05 (serial number less than 23J 9999999 999) ASTRO SIT FAST harnesses: C085AA00, C085AA01, C085AA02 (serial number less than 23J 9999999 999) CANYON GUIDE harnesses: C086BA00 and C086BA01 (serial number less than 23J 9999999 999) The affected harnesses have serial numbers below 23J 9999999 999. The serial number is located on the plastic label inside the waistbelt. The harnesses were manufactured before October 2023.

Why it was recalled

The screws on the gated ventral attachment point of the harnesses can prematurely wear and cause the ventral D-ring’s pin to release and attachment point to open.

Hazard

Risk of serious injury or death from falling if the screws wear out and the gated ventral attachment point of the harness opens.

Read the official notice ↗

Source: Product Safety Australia. RecallMatch AU provides a screening summary and is independent of the ACCC.